Drip Zone Valve Kit
Model 53749
Installation Instructions
Specifications
Kit Components
• Inlet/Outlet Pipe Connection: 3/4" Female NPT
• Maximum Supply Pressure: 150 PSI
• Downstream Pressure Regulation: 25 PSI
• Flow Rate @ 25 PSI: 0.25–8 GPM
• Filtration: 150 Count Stainless Mesh Screen
• Irrigation Control Valve:
• 3/4" (FPT X FPT) Ball Valve
• 3/4" (MPT X MPT) F Series Y-Filter, 150 Mesh
• 3/4" (FPT X FPT) Toro Jar Top Valve, Anti-Siphon (AVB)
• 3/4" NPT Close Nipple
• 3/4" (FPT X FPT) Pressure Regulator, 25 PSI at 0.25–8 GPM
• Automatic, Anti-Siphon, Toro Jar Top Model
• Manual Bleed and Flow Control
• 24 V a.c., 60 Hz Solenoid
Installation Procedure
CAUTION: When assembling the Drip Zone Valve
Kit components, use just 11⁄2 to 2 turns of Teflon
tape on male threads. Never use pipe dope.
To achieve a leak-free thread connection, turn the
male fitting until it is finger tight, then add one or
two more turns. Over-tightening can cause splitting
and failure of the female threads.
Bonnet Ring
Bonnet
Figure 1
Filter Screen
Important: Ensure the Y-Filter, Jar Top Valve and
Pressure Regulator are installed in the correct flow
orientation. Flow direction arrows are provided on each
component. Refer to Figure 1 and Figure 2.
Body
1. Using the Close Nipple, install the Ball Valve to the Jar
Top Valve inlet.
2. Remove the Bonnet Ring from the Y-Filter by turning
it counterclockwise. Remove the Bonnet and Filter
Screen. See Figure 1.
3. Install the Y-Filter inlet to the Jar Top Valve outlet.
4. Install the Pressure Regulator inlet to the Y-Filter outlet.
5. Reassemble the Y-Filter components.
Note: Valve must be
Figure 2
installed at least 6"
above the highest
emitter it controls.
Jar Top Valve
Note: Hand tighten the Bonnet Ring only – do not
over-tighten.
Close Nipple
Ball Valve
Important: Refer to the provided Toro Jar Top Valve,
Anti-Siphon (AVB) installation instructions for additional
important installation and operating information.
Y-Filter
6. To determine the recommended minimum/maximum
number of drip emitters per Jar Top valve, refer to the
table below.
Pressure
Regulator
From Water
Supply
To Emitters
For technical assistance, call 1-800-367-8676.
ꢀ
© 2005 The Toro Company, Consumer Division • An ISO 9000-certified Company
Form Number 373-0347 Rev. B
RELEASED Version ©Toro 2005-2005
|
Thule Automobile Accessories 847 User Manual
Toastmaster Mixer MAXHM5CAN User Manual
Toshiba Marine Radio A300 User Manual
Toshiba Surge Protector TVS XT120 347 User Manual
Toshiba Tablet wt200 User Manual
Trango Broadband Stereo System AO2500 3 PTM User Manual
Tributaries TV Cables HXC5 User Manual
Troy Bilt Log Splitter LS 33 TB User Manual
VeriFone Credit Card Machine TRANZ 460 User Manual
ViewSonic Car Video System VX715 User Manual